* RECOMMENDED * Firmware Flash Component for Windows - HPE MSA 1040/2040/1050/2050 Drive Models EH000300JWCPK, EH000600JWCPL, EH000900JWCPN By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Type: | Firmware - SAS Storage Disk | Version: | HPD6(4 Nov 2020) | Operating System(s): | Microsoft Windows Server 2012 R2 | Microsoft Windows Server 2016 | Microsoft Windows Server 2019 | Red Hat Enterprise Linux 6 Server (x86) | Red Hat Enterprise Linux 6 Server (x86-64) | Red Hat Enterprise Linux 7 Server | SUSE Linux Enterprise Server 11 (AMD64/EM64T) | SUSE Linux Enterprise Server 11 (x86) | SUSE Linux Enterprise Server 12 | SUSE Linux Enterprise Server 15 | VMware vSphere 5.5 | VMware vSphere 6.0 | VMware vSphere 6.5 | Microsoft Windows Server 2012 | File name: | cp045837.exe (7.5 MB) |
This Windows Smart Component contains a firmware update for 300GB/600GB/900GB 12G SAS 15K drive models EH000300JWCPK, EH000600JWCPL, EH000900JWCPN in HPE MSA 1040/2040/1050/2050 Storage System. Prerequisites:
WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage System. NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%CPQSYSTEMlogMSA-Date~Time~ControllerSerialNumber.log and flash summary is logged to %systemdrive%CPQSYSTEMlogcpqsetup.log. Shanwan driver download for windows. IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage System. IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing. To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: ea4c6c957862adc39b39c93480d0b7825ac4d92a2e753de574c1ad4fe8255666 | cp045837.exe |
Reboot Requirement: Reboot is not required after installation for updates to take effect and hardware stability to be maintained. Installation:
Instructions to Validate Windows Smart Component Executable: To verify the HPE SHA256 Authenticode digital signature, do the following steps: - Download cpxxxxxxx.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the 'License' field.
- Right-click the filename then select Properties.
- When the Properties window displays, click the Digital Signature tab.
- Select the entry in the Signature List where Digest algorithm is SHA256 and click the Details button.
- The signature status will display at the top of the Details dialog.
- If the signature message states that “This digital signature is OK.”, then the firmware package is authenticated as an HPE package.
- If the message “This digital signature is not OK.” displays, then do the following:
- Do not deploy the firmware.
- Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.
To verify the SHA256 hash value, do the following steps: - Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cpxxxxxxx.exe.
- Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.
- If the values match, then the integrity of the downloaded file has been verified.
- If the values do not match, do not deploy the file or its contents.
- Download the file a second time and compare the new hash value.
- If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.
Installation instructions using Smart Component: The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI). GUI option: - Place the downloaded firmware package in a temporary directory.
- Using Windows Explorer, navigate to the directory containing the download.
- Double click the executable file.
- Follow onscreen instructions. After you are prompted for logon information, enter credentials for an account with management access rights.
- Wait for the installation to complete. Upon completion, a confirmation message is displayed.
CLI option: - Place the downloaded firmware package in a temporary directory.
- Using Windows command prompt, navigate to the directory containing the download.
- Execute the Smart Component by entering the following command:
cpxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s where:
- ip_address is the management IP address of the array controller
- username is the username account with management rights
- password is the password for username
Instead of command line parameters you can use the following DOS environment variables: - oa_address: set this variable for the IP address of array controller
- oa_username : set this variable for the username of array controller
- oa_password : set this variable for the password of that username.
Wait for the installation to complete. Upon completion, a confirmation message is displayed. NOTE: - Stop all I/O to array before starting the firmware update.
- When prompted for logon information, enter credentials for an account with management access rights.
- For details on supported command options, see the online help by executing the command cpxxxxxx.exe /h or /?
- Smart component supports LDAP user authentication for only HPE MSA 1050/2050 Storage System.
End User License Agreements: HPE Software License Agreement v1 Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Important:
WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage System. NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%CPQSYSTEMlogMSA-Date~Time~ControllerSerialNumber.log and flash summary is logged to %systemdrive%CPQSYSTEMlogcpqsetup.log. Leverage our resources, experience and network to help you make the right moves for your career. We get to know you first so we can find the right fit. If you’re looking for professional careers, careers in aviation or careers in administration, trust the experts at Quanta. Quanta Networks is comprised of global team of network technology, telecom and Blockchain professionals. The core team of Quanta Networks have a combined 200 years of experience in the Telecommunications Networking industry. Quanta network & wireless cards driver download for windows 7. QUANTA NETWORKS IT & OT Solutions for the Modern Enterprise Outpace disruption with solutions that adapt to both IT and OT business models to gain a competitive advantage, improve operational efficiency and maximize profitability. IT Solutions OT Solutions SP Solutions. IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage System. IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing. Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems: - HPE MSA 1040 SAN LFF Storage
- HPE MSA 1040 SAN SFF Storage
- HPE MSA 1040 SAS LFF Storage
- HPE MSA 1040 SAS SFF Storage
- HPE MSA 2040 SAN LFF Storage
- HPE MSA 2040 SAN SFF Storage
- HPE MSA 2040 SAS LFF Storage
- HPE MSA 2040 SAS SFF Storage
- HPE MSA 2042 SAN LFF Storage
- HPE MSA 2042 SAN SFF Storage
- HPE MSA 2042 SAS LFF Storage
- HPE MSA 2042 SAS SFF Storage
- HPE MSA 1050 SAN LFF Storage
- HPE MSA 1050 SAN SFF Storage
- HPE MSA 1050 SAS LFF Storage
- HPE MSA 1050 SAS SFF Storage
- HPE MSA 2050 SAN LFF Storage
- HPE MSA 2050 SAN SFF Storage
- HPE MSA 2050 SAS LFF Storage
- HPE MSA 2050 SAS SFF Storage
- HPE MSA 2052 SAN LFF Storage
- HPE MSA 2052 SAN SFF Storage
- HPE MSA 2052 SAS LFF Storage
- HPE MSA 2052 SAS SFF Storage
- HPE MSA 2040 LFF Disk Enclosure
- HPE MSA 2050 LFF Disk Enclosure
- HPE MSA 2050 SFF Disk Enclosure
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following issue was fixed in this release of firmware: - This update improves performance for random read workloads with delays between reads.
WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage System. NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%CPQSYSTEMlogMSA-Date~Time~ControllerSerialNumber.log and flash summary is logged to %systemdrive%CPQSYSTEMlogcpqsetup.log. IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage System. IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing. Version:HPD6 (4 Nov 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following issue was fixed in this release of firmware: - This update improves performance for random read workloads with delays between reads.
Version:HPD5 (13 Jun 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following fixes were added to this version of firmware: - New servo which disables a feature that could cause unrecoverable data errors.
- A fix for an issue where the drive could become unresponsive after a hard reset.
Following enhancement was added to the Flash Engine, used with this version of Smart Component: - Enables support for LDAP user authentication for the following products only:
- HPE MSA 1050 Storage Array
- HPE MSA 2050 Storage Array
Version:HPD4 (28 Mar 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following fix was added to this version of firmware: - When performing format on drives with marginal servo flaws, it takes too long to format or format fails with 03/31 reported across the interface on subsequent commands. This firmware includes a change that moves the servo flaw characterization retries earlier in the sequence of format.
Following enhancement was added to this version of the firmware: - This firmware adds a feature that will periodically assess the health of the writer element of the head by verifying the data after a write operation to ensure more robust data integrity.
Following enhancement was added to the Flash Engine, used with this version of Smart Component: - Enables support to LDAP user authentication to HPE MSA 1050/2050 Storage Array.
Version:HPD3 (20 Dec 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following fixes were added to this version of firmware: - This firmware implements the Firmware Security Log Page.
- This firmware contains a change to prevent occasional command completion time of 4-5 seconds window, which happens when a command is received while the drive is still transitioning from active to Idle A.
Type: | Firmware - SAS Storage Disk | Version: | HPD6(4 Nov 2020) | Operating System(s): | Microsoft Windows Server 2012 | Microsoft Windows Server 2012 R2 | Microsoft Windows Server 2016 | Microsoft Windows Server 2019 | Red Hat Enterprise Linux 6 Server (x86) | Red Hat Enterprise Linux 6 Server (x86-64) | Red Hat Enterprise Linux 7 Server | SUSE Linux Enterprise Server 11 (AMD64/EM64T) | SUSE Linux Enterprise Server 11 (x86) | SUSE Linux Enterprise Server 12 | SUSE Linux Enterprise Server 15 | VMware vSphere 5.5 | VMware vSphere 6.0 | VMware vSphere 6.5 |
|
DescriptionThis Windows Smart Component contains a firmware update for 300GB/600GB/900GB 12G SAS 15K drive models EH000300JWCPK, EH000600JWCPL, EH000900JWCPN in HPE MSA 1040/2040/1050/2050 Storage System. Installation InstructionsPrerequisites:
WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage System. NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%CPQSYSTEMlogMSA-Date~Time~ControllerSerialNumber.log and flash summary is logged to %systemdrive%CPQSYSTEMlogcpqsetup.log. IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage System. IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing. To ensure the integrity of your download, HPE recommends verifying your results with this SHA-256 Checksum value: ea4c6c957862adc39b39c93480d0b7825ac4d92a2e753de574c1ad4fe8255666 | cp045837.exe |
Reboot Requirement: Reboot is not required after installation for updates to take effect and hardware stability to be maintained. Installation:
Instructions to Validate Windows Smart Component Executable: To verify the HPE SHA256 Authenticode digital signature, do the following steps: - Download cpxxxxxxx.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the 'License' field.
- Right-click the filename then select Properties.
- When the Properties window displays, click the Digital Signature tab.
- Select the entry in the Signature List where Digest algorithm is SHA256 and click the Details button.
- The signature status will display at the top of the Details dialog.
- If the signature message states that “This digital signature is OK.”, then the firmware package is authenticated as an HPE package.
- If the message “This digital signature is not OK.” displays, then do the following:
- Do not deploy the firmware.
- Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.
To verify the SHA256 hash value, do the following steps: - Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cpxxxxxxx.exe.
- Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.
- If the values match, then the integrity of the downloaded file has been verified.
- If the values do not match, do not deploy the file or its contents.
- Download the file a second time and compare the new hash value.
- If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.
Installation instructions using Smart Component: The Smart Component package is a self-extracting executable. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI). GUI option: - Place the downloaded firmware package in a temporary directory.
- Using Windows Explorer, navigate to the directory containing the download.
- Double click the executable file.
- Follow onscreen instructions. After you are prompted for logon information, enter credentials for an account with management access rights.
- Wait for the installation to complete. Upon completion, a confirmation message is displayed.
CLI option: - Place the downloaded firmware package in a temporary directory.
- Using Windows command prompt, navigate to the directory containing the download.
- Execute the Smart Component by entering the following command:
cpxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s where:
- ip_address is the management IP address of the array controller
- username is the username account with management rights
- password is the password for username
Instead of command line parameters you can use the following DOS environment variables: - oa_address: set this variable for the IP address of array controller
- oa_username : set this variable for the username of array controller
- oa_password : set this variable for the password of that username.
Wait for the installation to complete. Upon completion, a confirmation message is displayed. NOTE: - Stop all I/O to array before starting the firmware update.
- When prompted for logon information, enter credentials for an account with management access rights.
- For details on supported command options, see the online help by executing the command cpxxxxxx.exe /h or /?
- Smart component supports LDAP user authentication for only HPE MSA 1050/2050 Storage System.
Release NotesEnd User License Agreements: HPE Software License Agreement v1 Hewlett-Packard End User License Agreement
Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Important:
WARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage System. NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%CPQSYSTEMlogMSA-Date~Time~ControllerSerialNumber.log and flash summary is logged to %systemdrive%CPQSYSTEMlogcpqsetup.log. IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage System. IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing. Supported Devices and Features:
Firmware on the listed drives can be updated when attached to any of the following Storage Systems: - HPE MSA 1040 SAN LFF Storage
- HPE MSA 1040 SAN SFF Storage
- HPE MSA 1040 SAS LFF Storage
- HPE MSA 1040 SAS SFF Storage
- HPE MSA 2040 SAN LFF Storage
- HPE MSA 2040 SAN SFF Storage
- HPE MSA 2040 SAS LFF Storage
- HPE MSA 2040 SAS SFF Storage
- HPE MSA 2042 SAN LFF Storage
- HPE MSA 2042 SAN SFF Storage
- HPE MSA 2042 SAS LFF Storage
- HPE MSA 2042 SAS SFF Storage
- HPE MSA 1050 SAN LFF Storage
- HPE MSA 1050 SAN SFF Storage
- HPE MSA 1050 SAS LFF Storage
- HPE MSA 1050 SAS SFF Storage
- HPE MSA 2050 SAN LFF Storage
- HPE MSA 2050 SAN SFF Storage
- HPE MSA 2050 SAS LFF Storage
- HPE MSA 2050 SAS SFF Storage
- HPE MSA 2052 SAN LFF Storage
- HPE MSA 2052 SAN SFF Storage
- HPE MSA 2052 SAS LFF Storage
- HPE MSA 2052 SAS SFF Storage
- HPE MSA 2040 LFF Disk Enclosure
- HPE MSA 2050 LFF Disk Enclosure
- HPE MSA 2050 SFF Disk Enclosure
FixesUpgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following issue was fixed in this release of firmware: - This update improves performance for random read workloads with delays between reads.
ImportantWARNING! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. IMPORTANT: Ensure that no other user is performing administrative functions on the HPE MSA 1040/2040/1050/2050 Storage System. NOTE: Disk drive upgrades on the HPE MSA 1040/2040/1050/2050 is an offline process. All host and array I/O must be stopped prior to the upgrade. For more information, see the HPE Modular Storage Array Reference Guides. All firmware flash progress messages are logged to %systemdrive%CPQSYSTEMlogMSA-Date~Time~ControllerSerialNumber.log and flash summary is logged to %systemdrive%CPQSYSTEMlogcpqsetup.log. IMPORTANT: Please refer to the best practices document for special considerations regarding the pre-install conditions for flashing hard drives in HPE MSA 1040/2040/1050/2050 Storage System. IMPORTANT: HTTPS or Telnet service must be enabled on the arrays being updated and the corresponding connection must not be blocked by any firewall on the host system where the smart component is being executed. The Smart Component will manage the SFTP/FTP settings and PFU settings (enabled or disabled) in the arrays during flashing. Revision HistoryVersion:HPD6 (4 Nov 2020) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following issue was fixed in this release of firmware: - This update improves performance for random read workloads with delays between reads.
Version:HPD5 (13 Jun 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following fixes were added to this version of firmware: - New servo which disables a feature that could cause unrecoverable data errors.
- A fix for an issue where the drive could become unresponsive after a hard reset.
Following enhancement was added to the Flash Engine, used with this version of Smart Component: - Enables support for LDAP user authentication for the following products only:
- HPE MSA 1050 Storage Array
- HPE MSA 2050 Storage Array
Version:HPD4 (28 Mar 2019) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following fix was added to this version of firmware: - When performing format on drives with marginal servo flaws, it takes too long to format or format fails with 03/31 reported across the interface on subsequent commands. This firmware includes a change that moves the servo flaw characterization retries earlier in the sequence of format.
Following enhancement was added to this version of the firmware: - This firmware adds a feature that will periodically assess the health of the writer element of the head by verifying the data after a write operation to ensure more robust data integrity.
Following enhancement was added to the Flash Engine, used with this version of Smart Component: - Enables support to LDAP user authentication to HPE MSA 1050/2050 Storage Array.
Version:HPD3 (20 Dec 2017) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Following fixes were added to this version of firmware: - This firmware implements the Firmware Security Log Page.
- This firmware contains a change to prevent occasional command completion time of 4-5 seconds window, which happens when a command is received while the drive is still transitioning from active to Idle A.
|
|